Hospital-Grade Sterilization & Clinical Safety
Your safety and peace of mind are non-negotiable. At Blanco Aesthetics in Khar West, every instrument, treatment chair, and air pathway follows strict international infection control protocols aligned with European EN 13060, NABH, and CDC standards.
Class B
Vacuum Autoclave
6-Stage
Instrument Cycle
HEPA 14
Air Purification
100%
Single-Use Barriers

EN 13060 Certified
European Class B Autoclave

Dr. Reshma Chawla
Lead Clinical Director • DCI Registered MDS
Zero Cross-Contamination Guarantee
Standard Operating Procedure
Our 6-Step Instrument Sterilization Cycle
Every reusable clinical instrument undergoes a rigorous, multi-tier decontamination lifecycle before being approved for use.
Ultrasonic Scrubbing
Instruments are immersed in an ultrasonic bath to dislodge micro-debris from hinges and crevices using high-frequency cavitation.
Enzymatic Decontamination
Submersion in hospital-grade multi-enzyme solutions breaks down organic matter, proteins, and bio-burden at the molecular level.
Hermetic Pouch Sealing
Instruments are thoroughly dried and sealed in medical-grade sterilization pouches with heat-activated chemical indicator strips.
Class B Vacuum Autoclave
Sterilization under high-pressure steam at 134°C in a European Class B vacuum autoclave, eliminating 100% of bacterial spores, viruses, and pathogens.
UV-C Storage Cabinets
Sterilized pouches are stored in dedicated Ultraviolet-C germicidal chambers to maintain complete sterile integrity until the moment of use.
Chairside Unsealing
The sterile pouch is verified and opened exclusively in front of the patient once you are seated in the dental operatory.
Complete Environmental Care
Total Operatory Disinfection
Beyond instruments, we maintain rigorous environmental standards covering air purity, waterline hygiene, and surface barriers.
HEPA 14 Air Filtration
Continual air exchange with medical-grade HEPA filters and aerosol extractors eliminating 99.97% of airborne micro-particles and aerosol droplets.
Distilled Water Lines
Our dental chairs use independent distilled water systems with anti-retraction valves to prevent any backflow contamination.
Barrier Film Protection
Light handles, chair controls, and dental motors are covered with single-use barrier films that are replaced after every patient.
FAQ
Frequently Asked Questions About Hygiene & Sterilization
Have questions about our infection control standards? We are proud to share our clinical sterilization protocols with every patient.
Visit our clinic
Experience our clean, sanitized clinical space in Khar West.
How are instruments sterilized between patients at Blanco Aesthetics?▼
All metallic instruments undergo a 6-step sterilization cycle: ultrasonic decontamination, enzymatic cleaning, medical pouch sealing with chemical indicator strips, and high-pressure Class B vacuum autoclave sterilization at 134°C. Pouches are only opened directly in front of the patient.
What items are strictly single-use disposables?▼
We use 100% disposable gloves, face masks, suction tips, patient drapes, headrest covers, protective surface barrier films, micro-brushes, and irrigation needles. These are disposed of immediately after each appointment according to bio-medical waste safety norms.
How is the clinical environment disinfected between appointments?▼
Our operatories undergo complete surface decontamination with hospital-grade, broad-spectrum antiviral and antibacterial disinfectant wipes between every patient. All touchpoints, light handles, and dental chair surfaces are protected with fresh barrier film.
How do you ensure clean air quality and aerosol control?▼
The clinic features high-volume extraoral suction systems and medical-grade HEPA 14 air filtration units that continuously purify indoor air, capturing 99.97% of airborne micro-particles and aerosol droplets.
Your health and safety in trusted hands.